Q52
A centrifugal pump is used to pump water through a horizontal distance of 150 m, and then raised to an overhead tank 10 m above. The pipe is smooth with an I.D. of 50 mm. What head (m of water) must the pump generate at its exit (E) to deliver water at a flow rate of 0.001 m3/s? The Fanning friction factor, f is 0.0062.
A.
10 m
B.
11 m
AnswerC.
12 m
D.
20 m
Answer: Option B
Solution
Answer: Option B
No explanation is given for this question Let's Discuss on Board