Vidyalelo
ECE · Q207

Measurement And Instrumentation

Engineering and GATE · ECE · question 207

Q207

A peak-responding ac voltmeter employing a half-wave precision rectifier has been calibrated to give a reading of 1 V for 1 V rms sinusoidal input. For 1 V dc input, the meter reading will be

A.
0.707 V
Answer
B.
0.707 V or 0 V
C.
1.414 V
D.
1.414 V or 0 V

Answer: Option A

Solution

Answer: Option A
No explanation is given for this question Let's Discuss on Board