Vidyalelo
Civil Engineering · Q24

RCC Structures Design

Engineering and GATE · Civil Engineering · question 24

Q24

A singly reinforced concrete beam of 25 cm width and 70 cm effective depth is provided with 18.75 cm2 steel. If the modular ratio (m) is 15, the depth of the neutral axis, is

A.
20 cm
B.
25 cm
C.
30 cm
Answer
D.
35 cm

Answer: Option C

Solution

Answer: Option C