Vidyalelo
Chemical Engineering · Q185

Mass Transfer

Engineering and GATE · Chemical Engineering · question 185

Q185

Pick out the wrong statement.

A.
Different solids have different equilibrium moisture curves
B.
Total condenser or reboiler is considered equivalent to one theoretical plate in McCabe-Thiele method of theoretical plate calculation for distillation column
C.
Heat removal load on cooler remains constant, even with increase of the reflux ratio in a distillation column
Answer
D.
Even a forced draft cooling tower can not cool water below the wet bulb temperature

Answer: Option C

Solution

Answer: Option C
No explanation is given for this question Let's Discuss on Board