Q19
The connection of intermediate vertical stiffeners to the web, not subjected to external loads, shall be designed for a minimum shear force (kN/m) of (where, t = the web thickness in mm h = the outstand of stiffener in mm)
A.
75 t2/h
B.
125 t3/h2
C.
125 t2/h
AnswerD.
175 t2/h
Answer: Option C
Solution
Answer: Option C