The C.O.P. of a refrigerator working on a reversed Carnot cycle is (where T1 = Lowest absolute temperature and T2 = Highest absolute temperature)

A.
Answer
B.
C.
D.

Answer: Option A

Solution

Answer: Option A
Solution:
The C.O.P. of a refrigerator working on a reversed Carnot cycle is
Where
T1 = Lowest absolute temperature,
T2 = Highest absolute temperature