Vidyalelo
Mechanical Engineering · all questions

Refrigeration And Air Conditioning
practice.

Practice every MCQ with options. Use Show answers when you want the correct option and solution.

285

Questions

1/15

Page

Pick an option on a question to see the right answer and solution.

Nusselt number (NN) is given by

Select an option to see the answer and solution.

In case of sensible heating of air, the coil efficiency is given by (where B.P.F. = Bypass factor)

Select an option to see the answer and solution.

The undesirable property of a refrigerant is

Select an option to see the answer and solution.

The desirable property of a refrigerant is

Select an option to see the answer and solution.

The operating pressure for refrigerating units using R-12 as a refrigerant is

Select an option to see the answer and solution.

Cooling water is required for following equipment in ammonia absorption plant

Select an option to see the answer and solution.

The coefficient of performance of a domestic refrigerator is ________ as compared to a domestic air-conditioner.

Select an option to see the answer and solution.

In aqua ammonia and Lithium bromide water absorption refrigeration systems, the refrigerants are respectively

Select an option to see the answer and solution.

In order to cool and dehumidify a stream of moist air, it must be passed over the coil at a temperature

Select an option to see the answer and solution.

During heating and dehumidification process, dry bulb temperature

Select an option to see the answer and solution.

During cooling and dehumidification, dry bulb temperature

Select an option to see the answer and solution.

In a domestic vapour compression refrigerator, the refrigerant commonly used is

Select an option to see the answer and solution.

In refrigerators, the temperature difference between the evaporating refrigerant and the medium being cooled should be

Select an option to see the answer and solution.

The minimum temperature to which water can be cooled in a cooling tower is

Select an option to see the answer and solution.

Air refrigeration cycle is used in

Select an option to see the answer and solution.

The value of C.O.P. in vapour compression cycle is usually

Select an option to see the answer and solution.

The specific humidity during cooling and dehumidification

Select an option to see the answer and solution.

The suction pipe diameter of refrigerating unit compressor in comparison to delivery side is

Select an option to see the answer and solution.

In a vapour compression refrigeration system, a throttle valve is used in place of an expander because

Select an option to see the answer and solution.

In a refrigeration system, heat absorbed in comparison to heat rejected is

Select an option to see the answer and solution.