In a shunting signal if the red band is inclined at 45° it indicates
A. Stop
B. Proceed
C. Proceed cautiously
D. None of the above
Select an option to see the answer and solution.
The nominal size of ballast used for points and crossings is
A. 25 mm
B. 40 mm
C. 50 mm
D. 10mm
Select an option to see the answer and solution.
The standard length of rail for Broad Gauge and Meter Gauge are respectively
A. 12 m and 12 m
B. 12 m and 13 m
C. 13 m and 12 m
D. 13 m and 13 m
Select an option to see the answer and solution.
Number of keys used in CST-9 sleeper is
A. 2
B. 3
C. 4
D. none of the above
Select an option to see the answer and solution.
Gauge is the distance between
A. center to center of rails
B. running faces of rails
C. outer faces of rails
D. none of the above
Select an option to see the answer and solution.
Normally the limiting value of cant is (where G is the gauge)
Select an option to see the answer and solution.
Tensile strength of steel used in rails should not be less than
A. 450 MPa
B. 500 MPa
C. 700 MPa
D. 850 MPa
Select an option to see the answer and solution.
Largest dimension of a rail is its
A. height
B. foot width
C. head width
D. any of the above
Select an option to see the answer and solution.
For the purpose of track maintenance, the number of turn out equivalent to one track km are
Select an option to see the answer and solution.
Due to battering action of wheels over the end of the rails, the rails get bent down and are deflected at ends. These rails are called
A. Roaring rails
B. Hogged rails
C. Corrugated rails
D. Buckled rails
Select an option to see the answer and solution.
Yellow lighthand signal indicates
A. stop
B. proceed
C. proceed cautiously
D. none of the above
Select an option to see the answer and solution.
Consider the following statements about concrete sleepers. 1. They improve the track modulus. 2. They have good scrap value. 3. They render transportation easy. 4. They maintain the gauge quite satisfactorily. Of these statements
A. 1 and 2 are correct
B. 2 and 3 are correct
C. 3 and 4 are correct
D. 1 and 4 are correct
Select an option to see the answer and solution.
Consider the following statements: Automatic signalling system results in 1. greater risk 2. higher efficiency 3. avoidance of block instruments 4. higher operating cost Of these statements
A. I and 2 are correct
B. 3 and 4 are correct
C. 1 and 4 are correct
D. 2 and 3 are correct
Select an option to see the answer and solution.
Minimum composite sleeper index pres-cried on Indian Railways for a track sleeper is
Select an option to see the answer and solution.
The distance through which the tongue rail moves laterally at the toe of the switch for movement of trains is called
A. flangeway clearance
B. heel divergence
C. throw of the switch
D. none of the above
Select an option to see the answer and solution.
The type of bearing plate used in all joints and on curves to give better bearing area to the rails is
A. flat mild steel bearing plate
B. mild steel canted bearing plate
C. cast iron anti creep bearing plate
D. none of the above
Select an option to see the answer and solution.
Standard size of wooden sleeper for Broad Gauge track is
A. 275x25x13 cm
B. 180x20x11.5 cm
C. 225x23x13 cm
D. 250x26x12 cm
Select an option to see the answer and solution.
Maximum value of ‘throw of switch’ for Broad Gauge track is
A. 89 mm
B. 95 mm
C. 100 mm
D. 115 mm
Select an option to see the answer and solution.
The purpose of providing fillet in a rail section is to
A. Increase the lateral strength
B. Increase the vertical stiffness
C. Avoid the stress concentration
D. Reduce the wear
Select an option to see the answer and solution.
A Broad Gauge branch line takes off as a contrary flexure from a main line If the superelevation required for branch line is 10 mm and cant deficiency is 75 mm, the superelevation to be actually provided on the branch line will be
A. 10 mm
B. 64 mm
C. 85 mm
D. 65 mm
Select an option to see the answer and solution.